Measurements units

RETMAP works with six main metrics: pressure, temperature, loading, potential, volume, and density. These metrics are stored and processed using the following units: MPa, K, mg/g, kJ/mol, ml/g, and kg/m3. As such, all values provided inside the configuration file (e.g. PREDICTION_TEMPERATURES) should be provided using the aforementioned units. However, the user can specify inside the configuration file if the data read from the input files is provided in different units, in which case conversion factors are used to reach the default units. Similarly, the user can specify the units used for writing the results.

Currently, the following measurement units are supported:

TEMPERATURE_UNITS, OUTPUT_TEMPERATURE_UNITS (default: K, type: String)

These keywords can be used to specify the measurement unit for temperature for the input and output files, respectively. The keyword TEMPERATURE_UNITS only applies to the data read from isobars and isosteres, and not to the input provided inside the configuration file. Moreover, it accepts an entry for each input data file. The keyword OUTPUT_TEMPERATURE_UNITS is used for both writing the results to files and plotting the results. However, the retmap.out file will still use the standard units. Only one output unit can be provided.

Options: K, R

PRESSURE_UNITS, OUTPUT_PRESSURE_UNITS (default: MPa, type: String)

These keywords can be used to specify the measurement unit for pressure for the input and output files, respectively. The keyword PRESSURE_UNITS only applies to the data read from isotherms and isosteres, and not to the input provided inside the configuration file. Moreover, it accepts an entry for each input data file. The keyword OUTPUT_PRESSURE_UNITS is used for both writing the results to files and plotting the results. However, the retmap.out file will still use the standard units. Only one output unit can be provided.

Options: MPa, kPa, Pa, bar, atm, Torr, mmHg

LOADING_UNITS, OUTPUT_LOADING_UNITS (default: mg/g, type: String)

These keywords can be used to specify the measurement unit for loading for the input and output files, respectively. The keyword LOADING_UNITS only applies to the data read from isotherms and isobars, and not to the input provided inside the configuration file. Moreover, it accepts an entry for each input data file. The keyword OUTPUT_LOADING_UNITS is used for both writing the results to files and plotting the results. However, the retmap.out file will still use the standard units. Only one output unit can be provided.

Options: mg/g, g/kg, mol/kg, mmol/g, cm3/g, mm3/mg, dm3/kg, l/kg, ml/g

POTENTIAL_UNITS, OUTPUT_POTENTIAL_UNITS (default: kJ/mol, type: String)

These keywords can be used to specify the measurement unit for potential energy for the input and output files, respectively. The keyword POTENTIAL_UNITS only applies to the data read from characteristics. Moreover, it accepts an entry for each input data file. The keyword OUTPUT_POTENTIAL_UNITS is used for both writing the results to files and plotting the results. However, the retmap.out file will still use the standard units. Only one output unit can be provided.

Options: kJ/mol, J/mol

VOLUME_UNITS, OUTPUT_VOLUME_UNITS (default: ml/g, type: String)

These keywords can be used to specify the measurement unit for volume for the input and output files, respectively. The keyword VOLUME_UNITS only applies to the data read from characteristics. Moreover, it accepts an entry for each input data file. The keyword OUTPUT_VOLUME_UNITS is used for both writing the results to files and plotting the results. However, the retmap.out file will still use the standard units. Only one output unit can be provided.

Options: ml/g, l/kg, cm3/g, dm3/kg

OUTPUT_DENSITY_UNITS (default: kg/m3, type: String)

The keyword OUTPUT_DENSITY_UNITS is used for both writing the results to files and plotting the results. However, the retmap.out file will still use the standard units. Only one output unit can be provided.

Options: kg/m3